Engine
Coolants Heat
Transfer Fluids Engine
Test Fluids Product
Information leaflets
Material
Safety Data Sheet
Freecor SPC
Description
Freecor SPC
- mixed with the appropriate amount of water - is used as a cooling and
heat transferring fluid in combustion engines. The heat of the internal
combustion is transferred via the fluid to the radiator where the
mixture is cooled by means of air flow. Formulated with powerful and
efficient additives,
Freecor SPC
is recommended for use in cooling systems of all types of liquid cooled
automotive, heavy duty and industrial internal combustion engines.
Freecor
SPC is an ethylene glycol based
fluid that provides efficient protection against freezing and boiling,
but also against corrosion. Exempt from potentially harmful additives
such as nitrites, amines and phosphates, the coolant also contributes to
a safer environment.
Freecor SPC is designed especially to meet the
requirements of engine manufacturers that require hybrid coolants to
protect modern Aluminum engines.
Benefits
Freecor SPC offers
the following benefits to the user :
| -Efficient and
long lasting corrosion protection |
combination of
silicate and carboxylate inhibitor technology
|
| -Excellent
silicate stability
|
high-performing
silicate stabiliser
|
| -Maintenance
free protection against freezing and boiling |
ethylene glycol
based fluid
|
| -Excellent
seal compatibility |
no adverse effects on rubber hoses
and gasket materials |
Application
Freecor SPC
provides year-round freezing and
corrosion protection. To ensure good corrosion protection it is
recommended to use at least 33 vol. % of
Freecor SPC
in the coolant solution. This provides freezing protection to -20°C.
Typical mixtures in Northern Europe are 50/50
Freecor SPC
/ water, offering freezing protection
down to -40°C. Mixtures with more than 70 vol. % of
Freecor SPC
in
water are not recommended.
The maximum freezing protection
(about -69°C) is obtained at 68 vol. %
Freecor SPC.
The use of soft water is preferred
for dilution.
Freecor SPC
may be used with confidence in engines
manufactured from cast iron, aluminium or combinations of the two
metals, and in cooling systems made of aluminium or copper alloys.
Exclusive use of
Freecor SPC
is recommended for optimal corrosion protection and sludge control. This
coolant is compatible with European hard tap waters. It satisfies the
most stringent requirements for hard water stability.

Chemical and Physical
Properties
| |
Freecor SPC
|
ASTM
D3306
requirements |
Method
|
| Ethylene
glycol |
> 90%
w/w glycol |
base |
|
| Inhibitor
content |
> 5%
w/w |
|
|
|
Water
content |
4%
w/w max. |
5%
w/w max. |
ASTM D1123 |
| Ash content |
1.6
% w/w typ. |
5%
w/w max. |
ASTM D1119 |
| Nitrite, amine, phosphate |
nil
|
|
|
| Colour |
colourless |
|
|
| Specific
gravity, 15°C |
1.122
typ. |
1.110
to 1.145 |
ASTM D4502 |
| Specific
gravity, 20°C |
1.118
typ. |
|
|
| Equilibrium
boiling point |
163°C
typ. |
>
163°C |
ASTM D1120 |
| Reserve
alkalinity (pH 5.5) |
16.5
typ.
|
report
|
ASTM D1121
|
| pH, 20°C
|
8.0
typ. |
|
ASTM D1287 |
| Refractive
Index, 20°C |
1.431
typ. |
|
ASTM D1218 |
| |
50%
dilution |
40%
dilution |
33%
dilution |
ASTM
3306 |
Method |
| pH |
8.6
typ. |
8.7
typ. |
8.8
typ. |
7.5 to 11.0 |
ASTM D1287 |
Foaming
properties at 25°C
Break time |
-
|
-
|
90ml
max.
14 sec typ. |
|
ASTM D1881
|
Foaming
properties at 88°C
Break time
|
35ml max.
1 sec typ. |
-
|
30ml max.
1 sec typ. |
150ml max.1
5 sec max.1 |
ASTM D1881
|
| Initial
crystallization |
<-37°C |
<-24°C |
<-16°C |
<-37°C |
ASTM D1177 |
| Freezing
protection |
-40°C typ. |
-26°C typ. |
-20°C typ. |
|
|
| Specific
gravity, 20°C |
1.072 typ. |
1.059 typ. |
1.048 typ. |
|
ASTM D4502 |
| Reserve
alkalinity (pH 5.5) |
8.5
typ.
|
6.8 typ.
|
5.6 typ.
|
|
ASTM D1121
|
|
Effect on non-metals |
no effect |
- |
- |
|
MTL5048 |
| Hard water
stability |
no
precipitate |
- |
- |
|
VW PV 1426
MTL 5048 |
1
limit for the 33% dilution
Corrosion
Protection Table
1 : ASTM D1384 glassware corrosion tests
| |
Weight loss in mg/coupon1 |
| |
Brass |
Copper |
Solder |
Steel |
Cast Iron |
Aluminium |
| ASTM
D3306 (max) |
10 |
10 |
30 |
10 |
10 |
30 |
|
Freecor SPC
|
2 |
1 |
1 |
0 |
0 |
-1 |
1
Weight loss AFTER chemical cleaning acc. to ASTM procedure. Weight gain
is indicated by a - sign.
Table 2: ASTM D4340 Aluminium heat
rejection test, 25%
| |
Weight loss in mg/cm2/week1 |
| ASTM D3306 (max) |
1.0 |
|
Freecor SPC |
<-0.2 |
1
Weight loss AFTER chemical cleaning acc. to ASTM procedure. Weight gain
is indicated by a - sign.
Table 3 : MTU Dynamic Hot
Corrosion Test (MTV5061 - 48 h, 1890W)
| |
Cast Iron
|
Aluminum |
|
Non heated
|
Heated
|
Non heated
|
Heated
|
|
Weight loss1 |
Weight loss1 |
Temp increase2
|
Weight loss1 |
Weight loss1 |
Temp increase2
|
MTL 5048 (max)
40v%
20v%
|
10
80 |
30
800 |
< 10°C
< 10°C |
10
80 |
30
800 |
< 10°C
< 10°C |
Freecor SPC
40v%
3
20v%
3 |
3
7 |
16
14 |
< 10°C
< 10°C |
4
6 |
10
9 |
< 10°C
< 10°C |
1
Weight loss is expressed as mg/coupon, AFTER chemical
cleaning acc. to (shortened) MTU procedure. Weight gain is indicated by
a – sign.
2
Temperature increase of the heated coupon
3
Dilution in deionised water
Remark:
At both concentrations no deposit formation is observed
Approvals by OEM's & National
Authorities
Freecor SPC
has been approved by quite a fex engine manufacturers
or is in test with several other OEMs.
Availability
Freecor SPC
is currently available in bulk . Please contact your local Arteco Area
Sales Manager on availability of packages, dilutions and colours or
customer adapted variants.
Storage Requirements
The product should be stored at ambient
temperatures and periods of exposure to temperatures above 35°C should
be minimized.
Freecor SPC
can be stored for minimum 2 years in unopened containers without any
effect on the product quality or performance. It is strongly
recommended to use new containers and not recycled ones. As with any
antifreeze coolant, the use of galvanized steel is not recommended for
pipes or any other part of the storage/mixing installation.
Toxicity & Safety
For Toxicity and Safety Data we refer to the
Material Safety Data Sheet. The transport is not regulated. Labeling
as for any MEG based coolant is required: Xn: R 22 (Harmful if
swallowed) and S 2 (Keep out of reach of children). This product should
not be used to protect the inside of drinking water systems against
freezing.
All information contained in this Product Information Leaflet is accurate to the best of our knowledge and belief as at the date of issue specified. However, the Company makes no warranty or representation, express or implied, as to the completeness of such information.
|